Although
the periodic maintenance of UPS power supply is less, but these contents are
very necessary,And these maintenances must have a set
of strict procedures. For example, maintenance personnel do not regularly
maintain equipment as required, which is one of the important reasons for the
failure of UPS power supply.
1. The
use of UPS power supply should be in a well-ventilated, heat-dissipating and
clean, tidy and dust-free environment。
2. During
the use of the UPS power supply, do not bring inductive loads to avoid damage.
3. The
output load of the UPS power supply should be controlled within a certain
range, 50%-80% is better, neither too high nor too low, thus affecting the
service life of the UPS power supply。
4. Proper
discharge is helpful for the activation of the battery. For example, if the
mains power is not interrupted for a long time, the mains power should be
manually cut off and the UPS power supply should be discharged once every three
months with the load, which can prolong the service life of the battery.
5. When
using, you should pay attention to the sequence of switching on and off. When
starting up, the UPS power should be turned on first, and then the loads should
be turned on one by one, so as to avoid the impact of the load current on the
UPS power supply and prolong the service life of the UPS. When shutting down,
the loads should be turned off one by one, and then the UPS power should be
turned off.
6. After
the UPS is discharged, it should be charged in time to avoid damage to the
battery due to excessive self-discharge.
Due to
the battery, the reliability of the UPS alone cannot ensure safe power supply
services in emergency situations, and is misled by the manufacturer's
"maintenance-free", resulting in 90% of the batteries lacking
maintenance,the battery usually changes from good to
bad within a week or two, and in extreme cases, it deteriorates in just 2 days.
Therefore, for the core backup power system, only quarterly maintenance is far
from enough.
The scientific and effective battery maintenance method at this stage is to install a battery online monitoring system for the battery pack,Real-time online monitoring of important parameters such as voltage, internal resistance, temperature, and battery leakage of single cells,Once a parameter is found to be abnormal, an alarm will be issued immediately, which can prompt the maintainer to find problems or potential hidden dangers and deal with them in time. Thereby, the failure rate of the UPS is greatly reduced, a lot of human and financial resources are saved, and the safe operation of the UPS power system is ensured.